Acoustic Solutions

CPCB-Compliant Acoustic Enclosures
for DG Sets & Industrial Generators

KBG Group designs and manufactures acoustic enclosures achieving 25–35 dB(A) noise reduction — meeting CPCB E(P) Act noise emission standards for diesel generators in commercial, industrial, hospital, and data centre applications. Available for 250 kVA to 3000 kVA generator capacity range.

25–35
dB(A)
Noise Reduction
CPCB
Compliant
250–3000
kVA
Capacity Range
15 Days
Standard Delivery
Applicable Standards
CPCB E(P) Act · IS 12213 · BS EN ISO 3741 · EN 13030 · IS 15879 · ISO 9001:2015
Regulatory Context

Why DG Set Noise Compliance Is Mandatory

The Central Pollution Control Board (CPCB) has mandated noise emission limits for diesel generators under the Environment (Protection) Act. Non-compliance attracts notices, fines, and facility shutdown orders.

Regulatory Requirement

CPCB Noise Limits

Daytime noise limit: 75 dB(A) at 1m from the enclosure. Night-time limit: 70 dB(A). Applies to all DG sets above 5 kVA. Generators without compliant enclosures are in violation of the E(P) Act, 1986.

Unenclosed DG Set:
Typical noise level: 95–105 dB(A) at 1m
Engineering Approach

Insertion Loss Design

KBG enclosures are designed using double-skin panel construction with high-density mineral wool or rockwool infill. Panel NRC (Noise Reduction Coefficient) is calculated to achieve the required insertion loss at each octave band frequency.

Core density options:
48 kg/m³ (standard) · 64 kg/m³ · 96 kg/m³ (high IL)
KBG Solution

Compliant in 15 Days

Submit DG set make, kVA rating, and acoustic brief. KBG designs and manufactures the enclosure with integrated AMCA-certified acoustic ventilation louvers, maintenance access doors, and fuel/exhaust pass-throughs. Delivered in 15 working days standard, 8 days expedited.

Post-installation noise reading:
Guaranteed ≤75 dB(A) at 1m (daytime limit)
Engineering Data

Acoustic Enclosure Technical Specifications

Standard parameters — all enclosures manufactured to generator-specific custom dimensions.

Sound Insertion Loss25–35 dB(A) standard range (design-specific)
Generator Capacity250 kVA – 3000 kVA (custom for any size)
Panel ConstructionDouble-skin GI (1.2mm + 0.8mm) with mineral wool infill
Core Density48 / 64 / 96 kg/m³ mineral wool or rockwool
FrameStructural steel, hot-dip galvanized (IS 2629)
VentilationIntegrated AMCA-certified acoustic louvers (IS 12433)
AccessHinged maintenance doors, removable inspection panels
Exhaust DuctFlexible bellows + acoustic attenuator silencer
Surface FinishPowder coat RAL 9002 / custom colour / mill finish

Standards & Compliance

  • CPCB E(P) Act DG Set Noise Emission Limits — primary compliance
  • IS 12213 Code of Practice — Acoustic Enclosures
  • BS EN ISO 3741 Acoustics — Sound Power Level Determination
  • IS 12433 Ventilation Louvers — integrated in all enclosures
  • IS 2629 Hot-Dip Galvanizing for structural frame
  • ISO 9001:2015 Quality Management System
Sectors Served

Industries Using KBG DG Set Enclosures

Data Centres
Tier III/IV facility backup generators requiring noise compliance in urban locations
Hospitals
Critical power backup for ICU and surgical facilities with strict acoustic environment requirements
Residential Townships
Society generators in residential zones with tight day/night noise limits
Industrial Plants
Standby and prime power DG sets for manufacturing facilities and warehouses
Commercial Buildings
Office complexes, malls, and IT parks with basement or rooftop DG room compliance
Telecom Towers
Remote and urban telecom DG installations requiring compact acoustic solutions
CPCB Compliance Enquiry

Get a CPCB Acoustic Compliance
Assessment for Your DG Set

Submit your DG set make, kVA rating, site boundary distance, and existing noise readings. Our acoustic engineers will provide a preliminary noise assessment and recommend the right enclosure specification to achieve CPCB compliance.

Information to share in enquiry:
  • DG set make, model, and kVA rating
  • Distance from generator to nearest site boundary
  • Existing measured noise level (if available)
  • Site plan or layout drawing (optional)
Submit Acoustic Enquiry View Noise Control Products