KBG Group
Metro Rail Solutions

Precision-Engineered Systems
for Metro Rail Infrastructure

KBG Group supplies ventilation louvers, acoustic enclosures, jet nozzle AHUs, and architectural facade systems to metro rail authorities and HVAC consultants across India and the GCC. Every product tested to EN 13030, compliant with IS 12433, and delivered with full material and performance documentation.

6+
Metro Projects
IS 12433
Compliant
EN 13030
Tested
Design-to-Install
Capability
Metro Rail Standards
IS 12433 · EN 13030 · IS 15879 · NBC 2016 · ECBC 2017 · UL 555 / UL 555S · ISO 9001:2015
Engineering Brief

Metro Rail Challenges We Solve

Metro rail environments impose exacting performance requirements — high airflow with zero water ingress, acoustic attenuation on concourses, and ECBC-compliant station facades. KBG systems are designed and tested to meet each constraint.

Concourse & Tunnel Ventilation

Underground concourse ventilation demands high free-area louvers with zero water penetration at design wind velocities. Our sand-trap and storm-rated louvers meet AMCA Class A–B penetration ratings per EN 13030, with aluminium blades engineered for corrosion resistance in humid tunnel environments.

Sand-Trap Louvers Storm-Rated AMCA Class A–B

Platform Acoustic Control

Train arrival and braking noise at platform level routinely exceeds 85 dB(A). KBG acoustic louvers and barrier systems deliver 20–30 dB(A) insertion loss, meeting CPCB E(P) Act and NGT noise standards. Mineral wool-lined absorptive panels with ventilation pass-through for equipment rooms.

20–30 dB(A) Loss CPCB Compliant IS 15879

Station Facade Integration

Metro station facades require ECBC 2017 compliant solar shading, architectural fins, integrated ventilation, and fire-rated dampers — all coordinated from a single fabrication source to reduce design interfaces and avoid schedule conflicts between trades.

ECBC 2017 Single-Source Supply BIM Coordination
Documentation

Technical Compliance for Metro Rail Specifications

All products supplied with test reports, material certificates, and submittal documentation aligned to metro authority vendor approval requirements.

IS 12433Ventilation Louver Dimensions & Air Performance — primary specification for all louver supply
EN 13030Air Performance & Water Penetration Testing — test reports available per lot
IS 15879Noise Barrier Specifications — applicable to acoustic panel and barrier systems
NBC 2016National Building Code — fire safety and life safety compliance for all dampers
ECBC 2017Energy Conservation Building Code — solar shading performance for facade systems
UL 555 / UL 555SFire & Smoke Damper Ratings — applicable to all damper supply in fire-rated partitions
ISO 9001:2015Quality Management System — certified manufacturing with traceable inspection records

DMRC / MMRDA / HMRL / BMRCL Approved Vendor status available on request. Contact us for vendor registration documentation.

Project References

Metro Rail Projects Delivered

Reliance Metro One
Metro Rail · Mumbai

Reliance Metro One

HVAC ventilation louvers and air distribution products for station concourse. Supplied to IS 12433 standard with full AMCA water penetration certification. Ongoing, 2024.

MMRDA Airport FOB
Aviation Infra · Mumbai

MMRDA Airport FOB

Ventilation and facade systems for foot over bridge connecting metro and airport terminal. MMRDA-approved vendor, supply and installation, 2023.

View Full Project Portfolio
Technical Enquiries

Submit Your Metro Rail
Project Specification

Our technical team responds within 4 working hours to metro rail specifications. Provide your project authority, louver schedule, acoustic brief, or facade drawings and we'll return a compliant product recommendation with full documentation package.

Submit Metro Rail Enquiry View Ventilation Louver Range